Atrial Septal Defect (ASD) Device Closure

  • Standard Cutoff: Age > 3 to 4 years or Weight > 15 kg.

  • Rationale: To safely accommodate the large delivery sheaths (8 to 12 French) without causing femoral vein thrombosis or iliac venous injury. The atrial septum must also be large enough to hold the device without impinging on the SVC, IVC, mitral valve, or aortic root.

  • Exception: Can be performed in younger/smaller children (< 10 kg) if they have severe intractable right heart failure, though surgical closure is often preferred in very small infants.



Patent Ductus Arteriosus (PDA) Device Closure

  • Standard Devices (e.g., Amplatzer Duct Occluder): Age > 6 months or Weight > 6 kg.

  • Premature Infants: Weight > 700 gm  using specifically designed micro-devices (e.g., Amplatzer Piccolo Occluder).

  • Rationale: Delivery sheaths for standard devices (6 to 7 French) pose a risk of femoral vascular injury in small infants. The Piccolo device can be delivered through a 4 French microcatheter.



Ventricular Septal Defect (VSD) Device Closure

  • Perimembranous VSD: Weight > 8 to 10 kg (typically age > 1 to 2 years).

  • Muscular VSD: Weight > 5 kg.

  • Rationale: In smaller hearts, the rigid device discs can impinge on the aortic valve (causing aortic regurgitation) or the tricuspid valve. There is also a significantly higher risk of procedure-induced Complete Heart Block (CHB) in smaller infants due to the proximity of the conduction system.



Coarctation of the Aorta (CoA) Interventions

  • Balloon Angioplasty: No minimum age or weight. Can be performed in neonates, primarily for post-surgical recoarctation or as a bridge to definitive therapy in critically ill infants.

  • Stenting: Age > 8 to 10 years or Weight > 25 kg.

  • Rationale for Stenting: A stented aortic segment will not grow with the child. Implantation is delayed until the child reaches a size where an adult-size stent can be safely delivered (requiring large sheaths) and subsequently post-dilated to adult dimensions (18 to 20 mm) as the child grows.



Transcatheter Pulmonary Valve Implantation (TPVI)

  • Standard Cutoff: Weight > 20 to 30 kg (typically > 7 to 10 years of age).

  • Rationale: This procedure utilizes large valves (e.g., Melody or SAPIEN) requiring massive delivery systems (22 to 24 French). Using these in smaller children guarantees severe iliofemoral vascular injury. Additionally, the existing RVOT conduit must be of a sufficient minimum diameter (usually > 16 mm).



Balloon Pulmonary Valvuloplasty (BPV) and Aortic Valvuloplasty (BAV)

  • Standard Cutoff: No minimum age or weight.

  • Rationale: Routinely and safely performed in neonates (including premature infants) on day one of life for Critical Pulmonary Stenosis or Critical Aortic Stenosis.



Major Aortopulmonary Collateral Artery (MAPCA) Coiling / Vessel Embolization

  • Standard Cutoff: No minimum age or weight.

  • Rationale: Can be performed in neonates utilizing 3 to 4 French microcatheters to deploy coils or vascular plugs in bleeding or excessive collateral vessels.



Balloon Atrial Septostomy (Rashkind Procedure)

  • Standard Cutoff: No minimum age or weight (typically a neonatal procedure).

  • Rationale: A life-saving emergency procedure performed in the first hours or days of life for Transposition of the Great Arteries (TGA) to ensure adequate mixing of blood.



Patent Foramen Ovale (PFO) Device Closure

  • Standard Cutoff: Typically Age > 18 years (for cryptogenic stroke protocols). In pediatric cases (e.g., platypnea-orthodeoxia syndrome or severe right-to-left shunting), Weight > 15 kg.

  • Rationale: The evidence base for PFO closure is predominantly in adults post-stroke. When indicated in children, the constraints are similar to ASD closure to accommodate 8 to 9 French delivery sheaths and ensure the device discs do not erode the adjacent structures.



Ductus Arteriosus Stenting (Ductal-Dependent Lesions)

  • Standard Cutoff: No minimum age or weight.

  • Rationale: This is a neonatal rescue or palliative procedure (an alternative to a surgical Blalock-Taussig shunt or continuous PGE1 infusion) for conditions like Pulmonary Atresia or severe Tetralogy of Fallot. It is performed in the first days of life, often in premature or low-birth-weight neonates.



Right Ventricular Outflow Tract (RVOT) Stenting

  • Standard Cutoff: No minimum age or weight.

  • Rationale: Used as early palliation for symptomatic neonates with Tetralogy of Fallot (to avoid early neonatal complete repair or surgical shunts). Standard coronary stents are typically deployed via 4 to 5 French sheaths.



Pulmonary Artery (PA) Branch Stenting

  • Standard Cutoff (Adult-Size Stents): Weight > 20 to 25 kg.

  • Standard Cutoff (Pre-mounted / Low-Profile Stents): Can be done in smaller children (Weight > 10 kg), but requires future re-intervention or surgical unzipping.

  • Rationale: Similar to aortic coarctation stenting, deploying a stent in a small child "locks" the vessel size. To safely deliver large-diameter, large-cell stents that can be serially dilated to adult dimensions (up to 18-20 mm) as the child grows, the femoral veins must be large enough to accept 10 to 12 French sheaths.



Ruptured Sinus of Valsalva (RSOV) Device Closure

  • Standard Cutoff: Weight > 15 to 20 kg.

  • Rationale: RSOV is rare in early childhood and typically presents in older children or adults. Closure requires larger delivery sheaths and poses a high risk of device impingement on the coronary ostia or aortic valve leaflets in smaller aortic roots.



Coronary Arteriovenous Fistula (CAVF) Closure

  • Standard Cutoff (Coils): No strict minimum; can be performed in infants.

  • Standard Cutoff (Vascular Plugs/Devices): Weight > 10 to 15 kg.

  • Rationale: Small fistulas in infants can be closed with micro-coils delivered through 4 French catheters. Large, high-flow fistulas require Amplatzer Vascular Plugs or similar devices, necessitating larger guide catheters (6 to 8 French) that are unsafe for neonatal arteries.



Fontan Fenestration Closure

  • Standard Cutoff: Typically performed 6 to 12 months post-Fontan completion (Age > 3 to 5 years).

  • Rationale: The patient must have established low pulmonary vascular resistance to tolerate the removal of the pop-off fenestration. It is performed using standard ASD/PFO occluders or vascular plugs.



Aortopulmonary (AP) Window Device Closure

  • Standard Cutoff: Highly individualized, but typically restricted to Weight > 10 to 15 kg for transcatheter candidates.

  • Rationale: AP windows are almost exclusively treated surgically in neonates due to the massive shunt and early heart failure. Transcatheter closure is reserved for small, restrictive defects or residual postoperative defects, requiring a patient large enough to tolerate the delivery system without compromising the origins of the coronary arteries.








Grown-Up Congenital Heart (GUCH) interventions and

Complex Palliative procedures. 


Stenting of Systemic Veins (SVC/IVC)

  • Standard Cutoff: Weight > 15 to 20 kg for definitive adult-sized stents.

  • Rationale: Seen in patients post-atrial switch (Mustard/Senning) or post-heart transplant presenting with baffle obstruction or caval stenosis. The femoral or jugular veins must be large enough to accommodate 10 to 12 French sheaths to deliver large-diameter (often 14 to 20 mm) stents.


Baffle Leak Device Closure

  • Standard Cutoff: Weight > 15 kg.

  • Rationale: Post-Mustard/Senning patients often develop baffle leaks leading to right-to-left shunting and cyanosis. Closure utilizes ASD or PFO occluders. The patient must be large enough to safely navigate large delivery sheaths through complex, reconstructed venous pathways without tearing the baffle.


Venovenous Collateral Embolization (Post-Glenn/Fontan)

  • Standard Cutoff: No minimum age or weight.

  • Rationale: Patients with a failing Fontan or Glenn often develop decompressing venovenous collaterals (e.g., SVC to pulmonary veins) leading to severe cyanosis. These can be coiled or plugged using low-profile 4 to 5 French diagnostic catheters at any age, provided the collateral is hemodynamically significant.


Transcatheter Creation/Enlargement of Atrial Communication (Beyond Rashkind)

  • Standard Cutoff: No minimum age or weight.

  • Rationale: For neonates with Hypoplastic Left Heart Syndrome (HLHS) and a highly restrictive or intact atrial septum, standard Rashkind septostomy fails. These neonates require transcatheter cutting balloon septoplasty or direct atrial septal stenting on day one of life to decompress the left atrium and prevent fatal pulmonary venous hypertension.


Paravalvular Leak (PVL) Closure

  • Standard Cutoff: Typically Adult/GUCH (Weight > 30 kg).

  • Rationale: Congenital patients with multiple prior surgical valve replacements (especially mechanical valves) can develop severe hemolytic anemia or heart failure from PVLs. This requires complex, often transseptal, navigation using 8 to 9 French steerable sheaths and specialized rectangular/square vascular plugs (e.g., Amplatzer Vascular Plug III), which cannot be safely maneuvered in pediatric hearts.


Transcatheter VSD Creation (Perventricular or Transcatheter)

  • Standard Cutoff: No minimum age or weight.

  • Rationale: A highly specialized, desperate salvage procedure for infants with restrictive right ventricles or severe pulmonary hypertension requiring a "pop-off" valve. It uses cutting balloons or RF transseptal needles followed by stenting of the ventricular septum, performed regardless of size to save the patient's life.